Special transformers for Railways

Our transformers are designed to withstand high mechanical stresses due to fluctuating load current and frequent short-circuits created by passing trains. With rated power up to 40 MVA and connection to HV up to 110kV, we can propose solutions for all situations.

To improve transmission efficiency and system regulation while reducing earth current and electromagnetic interferences, Setrans Holding proposes a full range of specific medium power transformers dedicated to railway power supply:

  • Standard Power Transformers
  • Autotransformers
  • Power Feeding Transformers

 

Special transformers for electro-intensive industries

MAIN CHARACTERISTICS

 Single phase or three phases

Rated Power

From 2 up to 63 MVA

Voltages

From 35kV to 220kV

Frequency

50 / 60 Hz

Cooling System

ONAN, ONAF, ODAF, OFAF, OFWF

Temperature

From -45°c to +40°C

Maintenance

Reduced to periodic checks

Electrical Arc Furnace

EAF Transformers operate under very severe conditions with regard to frequent overcurrents and overvoltages generated by short circuits in the furnace and the operating of HV circuit-breaker. SETRANS HOLDING compact and low-weight transformers fully comply with the customers’ specifications. They are rigorously adapted to support extreme thermal, mechanical and dielectric constraints of the furnace load cycle.

Electric Arc Furnaces (EAF) can be either of AC or DC arcfurnaces.

Rectifier Transformers

Especially designed to supply the extra-high currents required for industrial applications such as electrolysis and electrochemical processes, Setrans Holding proposes a complete offering adapted top both new or refurbished installations.

APPLICATIONS

Electro-intensive industries

  • Steel furnaces
  • Ferro-alloy furnaces with short or submerged arc
  • Smelting of other marerials

 

 

 

 

 

 

 

Instrument Transformers

We offer both instrument and current transformers for transferring or generating measurement signal.

INSTRUMENT CURRENT TRANSFORMERS
For electric measuring sensors and protection networks; alarm in the AC units with current of 50 and 60 Hz, 110 kV. Secondary current 5 А, primary current 75-150А, 150-300А, 100-200А, 300-600А.

INSTRUMENT VOLTAGE TRANSFORMERS
Measuring information signal for electric units and circuits protection; for alarming in network with grounded neutral on the AC units with frequency 50 and 60 Hz, 110 kV.

 

MV Switchgears

Widely used for power generation and transmission / distribution facilities used by power companies, industrial plants, buildings and switchgear facilities.

  • Compact and Simple Design
  • Safety Design
  • Low maintenance